MOST PAVE HERMETIC SEALS ARE BI-DIRECTIONAL SEALS FOR VACUUM OR PRESSURE.
PAVE-Mate© II has a single disconnect on one side and either insulated wire leads or terminals on the other side. Any connector series or type can be ordered either as a PAVE-Mate II style, including both high performance military or economical industrial metal, or plastic shell multi-pin connectors.
For Contact insert pin out lettering or number identifications, please click on the appropriate link below:
For PAVE-Mate Type 3112 bayonet disconnects based on MIL-C-26482 pin arrangements
For PAVE-MATE Type 3102 threaded coupling disconnects based on MIL-C5015 pin arrangements
For PAVE-MATE Type 27466, 27508, 99920, 99940 bayonet, threaded or push-pull disconnects based on MIL-C-38999 Series 1, 2, 3, or 4
Technical Data
Seal Integrity PAVE-Seal® PAVE-Mate®
PAVE-Optic-SealTM PAVE-Flex®
While all PAVE products will comply with helium leak rating from <10-6 cc/sec to 10-9 cc/sec (air equivalent) depending upon design, PAVE also uses more cost effective air bubble in fluid leak testing typically at 80 psi (5 bar). Special high pressure testing up to 10 k psi (600 bar) is also available.
HERMETIC EPOXY TEMPERATURE RATING
(Epoxy is proprietary and not sold separately)
PAVE Wire Seal® 150 -40° to 150° C
PAVE Wire Seal® 200 -60° to 200° C
PAVE Wire Seal® 200FR UL94V-O flame retardant
Toxicity Ratink K (NASA MAPTIS
Odor Rating A
Thermal Vacuum Stability Rating A
Flammability Rating X
FM Class 3600, EExd II 90° C TI
SPECIFICATIONS
Dielectric Strength >17.4 kV/mm
Dielectric Constant 5.3@ 1 Mhz
Volume Resisivity @ 125° C1x1015 Ohm-cm
Dissipation Factor 0.03 @ 1 Mhz
Hardness, Shore D 96
Low Vacuum Outgassing:
TML 0.25%
CVCM 0.01%
High Fungus Resistance MIL-STD–454J/4
Specific Gravity @ 25° C 2.3
Compressive Strength >948 kg/cm2
Compressive Modules 7.7×104 kg/cm2
Tensile Strength >470 kg/cm2
Water Absorption (24 hours) 0.03%
The PAVE-Seal® epoxy is impervious to most oils, solvents, fuels, freons, gases, etc. Epoxy samples are available upon request for customer’s evaluation for any specific chemical compatibility.
Any type or size of wire or cable may be specified including coaxial cables, thermocouple wire pairs, high voltage wires, fiber optic cable, flat cables, etc. for length.
NO DETECTABLE LEAKAGE THRU CONDUCTOR OR INSULATION.
Wire Conductor Gage (AWG) | O.D. | Amperage Rating | Nominal Insulation Overall | Nominal Insulation Diameter (O.D.) |
---|---|---|---|---|
30 | 0.30 mm | 2 | .03 | 0.8 mm |
28 | 0.40 | 2 | .04 | 1.0 |
26 | 0.50 | 3 | .05 | 1.3 |
24 | 0.60 | 3 | .06 | 1.5 |
22 | 0.78 | 4 | .06 | 1.5 |
20 | 0.90 | 6 | .07 | 1.9 |
18 | 1.21 | 8 | .08 | 2.0 |
16 | 1.50 | 10 | .09 | 2.3 |
14 | 1.85 | 18 | .11 | 2.8 |
12 | 2.4 | 25 | .12 | 3.0 |
10 | 2.94 | 40 | .21 | 5.3 |
6 | 4.67 | 80 | .26 | 6.6 |